Amplifier valves

Amplifier valves

Search Results for: Amplifier valves
direct acting relief valves bermad fire protection the bermad model fp- hc- is a direct acting, spring loaded, diaphragm type, relief valve. the single port is held closed buy the force of the adjustable spring located above the pressure sensing diaphragm. when the force of the pressure sensed under
rise nn easy in-field pressure setting adjustment nn ul/fm approved nn available in corrosion resistant materials nn tamperproof cap typical applications nn pressurized sprinkler systems nn fusible plug pilot lines nn thermal release for wet piping systems nn pressure relief for pressure control valves...
https://www.bermad.com/wp-content/uploads/FP-3HC-0_v18-1.pdf
constant downstream pressure, regardless of fluctuating demand or varying upstream pressure. the valve is equipped with a full opening eclectic override device. it reduces pressure loss across the valve to a minimum, in the event of a pressure drop below a minimum value. bermad sigma en/es series valves
are hydraulic, oblique pattern, globe valves with a raised seat assembly and double chamber unitized actuator, that can be disassembled from the body as a separate integral unit. the valves hydrodynamic body is designed for unobstructed flow path and provides excellent and highly effective modulation...
https://www.bermad.com/wp-content/uploads/WW_720-59-SIGMA_Product-Page_English_11-2017_smart-1.pdf
relief valve provides smooth drip tight closing. installation . ensure enough space around the valve assembly for future maintenance and adjustments. . prior to valve installation, flush the pipeline to insure flow of clean fluid through the valve. . for future maintenance, install isolation gate valves
should closing process causes system pressure rise. thus providing an "abs" closing characteristics. iom q trouble-shooting . valve fails to open: check for sufficient inlet pressure, confirm pilot setting & check cock valve status. . valve fails to close: confirm pilot setting, check cock & needle valves...
https://www.bermad.com/wp-content/uploads/WW_73Q_4-20-inch_IOM_English.pdf
signals, isolating the pump from the system during pump startup and shutdown, thereby preventing pipeline surges.while open, it sustains minimum pump discharge pressure regardless of fluctuating flow, and prevents the pump from exceeding its designed flow or power consumption. bermad sigma en/es series valves
are hydraulic, oblique pattern, globe valves with a raised seat assembly and double chamber unitized actuator, that can be disassembled from the body as a separate integral unit. the valves hydrodynamic body is designed for unobstructed flow path and provides excellent and highly effective modulation...
https://www.bermad.com/wp-content/uploads/WW_743-SIGMA_Product-Page_English_11-2017_smart.pdf
shuts off in response to electric signals, isolating the pump from the system during pump startup and shutdown, thereby preventing pipeline surges. while open, it maintains a pre-set maximum flow, preventing the pump from exceeding its designed flow or power consumption. bermad sigma en/es series valves
are hydraulic, oblique pattern, globe valves with a raised seat assembly and double chamber unitized actuator, that can be disassembled from the body as a separate integral unit. the valves hydrodynamic body is designed for unobstructed flow path and provides excellent and highly effective modulation...
https://www.bermad.com/wp-content/uploads/WW_747-U-SIGMA_Product-Page_English_11-2017_smart.pdf
reservoir level. during filling the valve sustains minimum upstream pressure regardless of fluctuating flow or reservoir level. reservoir filling is in response to a bi-level electric float switch signal opening at a pre-set low level and shutting off at a pre-set high level. bermad sigma en/es series valves
are hydraulic, oblique pattern, globe valves with a raised seat assembly and double chamber unitized actuator, that can be disassembled from the body as a separate integral unit. the valves hydrodynamic body is designed for unobstructed flow path and provides excellent and highly effective modulation...
https://www.bermad.com/wp-content/uploads/WW_753-65-SIGMA_Product-Page_English_11-2017_smart.pdf
pressure or reservoir level and protects the valve from cavitation damage. reservoir filling is in response to a hydraulically controlled non-modulating bi-level vertical float that opens at a pre-set reservoir low level and shuts off drip-tight at a pre-set high level. bermad sigma en/es series valves
are hydraulic, oblique pattern, globe valves with a raised seat assembly and double chamber unitized actuator, that can be disassembled from the body as a separate integral unit. the valves hydrodynamic body is designed for unobstructed flow path and provides excellent and highly effective modulation...
https://www.bermad.com/wp-content/uploads/WW_757-66-U-SIGMA_Product-Page_English_11-2017_smart.pdf
upstream pressure or reservoir level and protects the valve from cavitation damage. the valve shuts off at a pre-set reservoir high level and fully opens in response to an approximately one meter ( ft) level drop, as sensed by the -way altitude pilot mounted on the main valve. bermad sigma en/es series valves
are hydraulic, oblique pattern, globe valves with a raised seat assembly and double chamber unitized actuator, that can be disassembled from the body as a separate integral unit. the valves hydrodynamic body is designed for unobstructed flow path and provides excellent and highly effective modulation...
https://www.bermad.com/wp-content/uploads/WW_757-80-U-SIGMA_Product-Page_English_11-2017_smart.pdf
fluctuating demand or varying upstream pressure. installation . ensure enough space around the valve assembly for future maintenance and adjustments. . prior to valve installation, flush the pipeline to insure flow of clean fluid through the valve . for future maintenance, install isolation gate valves
a slow and controlled manner, the consumers line downstream from the pressure reducing system. . confirm that the supply pressure and the flow through the system are typical. if necessary, create flow by opening a hydrant, or reduce the flow/pressure by adjusting the downstream/upstream isolating valves...
https://www.bermad.com/wp-content/uploads/WW_820-PP_IOM_English.pdf
untold damage to property and even threaten human safety. many of these problems stem from water pressure fluctuations and can be prevented with proper water pressure control. at bermad, we take pride in developing pressure safety systems built to stabilize pressure spikes or drops. pressure safety valves
reservoirs and pressure control systems are important to ensure reliable / water supply with sufficient leeway. pressure spikes and water hammer are unwanted phenomena in high rise buildings that can affect the "pressure quality" in water supply systems and might even damage them. bermad level control valves...
https://blog.bermad.com/building-and-construction/rss.xml