request. the set flow is marked on the pilot label. allow the flow inspected in the system to stabilize, meeting the marked set flow. . if the set pressure is either different from the design or the requirements have been changed, change settings according to the following: . unlock the pilot locking nut
and slowly turn the pilot adjusting screw clock-wise to increase the set flow and counter clock-wise to decrease it. allow the ir- - -rub to react and the flow to stabilize. . after the flow is stabilized lock the pilot nut and open fully the downstream isolating valve. . check valve solenoid control...
https://www.bermad.com/wp-content/uploads/2016/05/IR-470-55-bRU.pdf
retighten the tube fitting. . the ir- -m - -kb is factory set according to the design. the set pressure is marked on the pilot label, if the set pressure is either different from the design or the requirements have been changed, change settings according to the following: . unlock the pilot locking nut
and slowly turn the pilot adjusting screw clock-wise to increase set pressure and counter clock-wise to decrease it. allow the ir- -m - -kb- to react and the downstream pressure to stabilize. . after the pressure is stabilized lock the pilot nut. . open fully the downstream isolating valve. . check...
https://www.bermad.com/wp-content/uploads/2016/05/IR-920-M0-55-bK.pdf
follow the steps described below: . close the upstream isolating valve to reduce ir- - -m -kx inlet pressure. ensure that the ir- - -m -kx sustains the upstream pressure, preventing it from decreasing below setting, even when the upstream isolating valve is almost closed. . unlock the pilot locking nut
and slowly turn the pilot adjusting screw clock-wise to increase set pressure and counter-clock-wise to decrease it. . after the pressure is stabilized, lock the pilot locking nut and open fully the upstream isolating valve. iom ir- -m - -kx trouble-shooting: symptoms cause remedy valve fails to open...
https://www.bermad.com/wp-content/uploads/2016/05/IR-930-M0-54-KX.pdf
changed follow the steps described below: . close the upstream isolating valve to reduce -m - -kx inlet pressure. ensure that the ir- -m - -kx sustains the upstream pressure, preventing it from decreasing below setting, even when the upstream isolating valve is almost closed. . unlock the pilot locking nut
and slowly turn the pilot adjusting screw clock-wise to increase set pressure and counter-clock-wise to decrease it. . after the pressure is stabilized, lock the pilot locking nut and open fully the upstream isolating valve . check valve solenoid control feature by de-energizing & energizing the solenoid...
https://www.bermad.com/wp-content/uploads/2016/05/IR-930-M0-55-KX.pdf
changed follow the steps described below: . close the upstream isolating valve to reduce ir- -m - -r inlet pressure. ensure that the ir- -m - -r sustains the upstream pressure, preventing it from decreasing below setting, even when the upstream isolating valve is almost closed. . unlock the pilot locking nut
and slowly turn the pilot adjusting screw clock-wise to increase set pressure and counter-clock-wise to decrease it. . after the pressure is stabilized, lock the pilot locking nut and open fully the upstream isolating valve . check valve solenoid control feature by de-energizing & energizing the solenoid...
https://www.bermad.com/wp-content/uploads/2016/05/IR-930-M0-55-R.pdf
request. the set flow is marked on the pilot label. allow the flow inspected in the system to stabilize, meeting the marked set flow. . if the set pressure is either different from the design or the requirements have been changed, change settings according to the following: . unlock the pilot locking nut
and slowly turn the pilot adjusting screw clock-wise to increase the set flow and counter clock-wise to decrease it. allow the ir- -m - -kv to react and the flow to stabilize. . after the flow is stabilized lock the pilot nut and open fully the downstream isolating valve. iom ir- -m - -kv trouble-shooting...
https://www.bermad.com/wp-content/uploads/2016/05/IR-970-M0-54-KV.pdf
request. the set flow is marked on the pilot label. allow the flow inspected in the system to stabilize, meeting the marked set flow. . if the set pressure is either different from the design or the requirements have been changed, change settings according to the following: . unlock the pilot locking nut
and slowly turn the pilot adjusting screw clock-wise to increase the set flow and counter clock-wise to decrease it. allow the ir- -m - -rvz to react and the flow to stabilize. . after the flow is stabilized lock the pilot nut and open fully the downstream isolating valve. . connect the remote control...
https://www.bermad.com/wp-content/uploads/2016/05/IR-970-MO-50-RVZ.pdf
request. the set flow is marked on the pilot label. allow the flow inspected in the system to stabilize, meeting the marked set flow. . if the set pressure is either different from the design or the requirements have been changed, change settings according to the following: . unlock the pilot locking nut
and slowly turn the pilot adjusting screw clock-wise to increase the set flow and counter clock-wise to decrease it. allow the ir- -m -kvz to react and the flow to stabilize. . after the flow is stabilized lock the pilot nut and open fully the downstream isolating valve. iom ir- -m -kvz trouble-shooting...
https://www.bermad.com/wp-content/uploads/2016/05/IR-970-MO-KVZ.pdf
pressure request. the set pressure is marked on the pilot's label. allow the pressure that appears in the downstream pressure gauge to stabilize, meeting the marked set pressure. . if the set pressure is either different from the design or the requirements have been changed, unlock the pilots locking nut
and slowly turn the pilot adjusting screw clock-wise to increase set pressure and counter -clock- wise to decrease it. allow the to react and the pressure to stabilize. . after the pressure is stabilized, lock the pilots locking nut and open fully the downstream isolating valve. . the restriction [...
https://www.bermad.com/wp-content/uploads/2016/06/ww-mun-iom-720-english.pdf
either different from the design or the requirements have been changed follow the steps described below: . simulate the requested ∆p by regulating the ∆p gauge high, low & bypass needle valves. note: when gauge ∆p is below the setting, the valve is closed and vice versa. . unlock the pilot locking nut
and slowly turn the pilot adjusting screw clock-wise until the valve close & seal. re-turn counter-clock-wise until the starts opening (leaking). . lock the pilot locking nut and confirm both upstream & downstream isolating valves are fully open. . the one way flow control [ ] is factory set fully open...
https://www.bermad.com/wp-content/uploads/2016/06/ww-mun-iom-736-english.pdf