after installation carefully inspect/correct any damaged accessories, piping, tubing, or fittings. commissioning & calibration: . confirm that the in-line filter ( a) arrow direction is in the valve flow direction. . confirm that the cock valve ( ) handle is turn to auto. . open fully the upstream isolating
valve and slowly open the downstream isolating valve, to fill-up, carefully, the consumers' line downstream from the valve. . vent air from the valve's control loop by loosening cover tube fitting at the highest point, allowing all air to bleed. then retighten the tube fitting. . the model ir- - -bd...
https://www.bermad.com/wp-content/uploads/2016/05/IR-170-54-bD.pdf
after installation carefully inspect/correct any damaged accessories, piping, tubing, or fittings. commissioning & calibration: . confirm that the in-line filter ( a) arrow direction is in the valve flow direction. . confirm that the cock valve ( ) handle is turn to auto. . open fully the upstream isolating
valve and slowly open the downstream isolating valve, to fill-up, carefully, the consumers' line downstream from the valve. . vent air from the valve's control loop by loosening cover tube fitting at the highest point, allowing all air to bleed. then retighten the tube fitting. . the model ir- -bdz...
https://www.bermad.com/wp-content/uploads/2016/05/IR-170-bDZ.pdf
correct any damaged accessories, piping, tubing, or fittings. commissioning & calibration: . confirm that the in-line filter arrow [ a] direction is in the valve flow direction. . allow the valve to start regulation by positioning the cock valve ( ) handle on port auto. . open fully the upstream isolating
valve and slowly open the downstream isolating valve, to fill-up, carefully, the consumers' line downstream from the valve. . vent air from the valve's control loop by loosening cover tube fitting at the highest point, allowing all air to bleed. then retighten the tube fitting. . the ir- - -kxz is factory...
https://www.bermad.com/wp-content/uploads/2016/05/IR-420-50-KXZ-iom-1.5-4inch.pdf
carefully inspect/correct any damaged accessories, piping, tubing, or fittings. commissioning & calibration: . confirm that t the in-line filter ( a) arrow direction is in the valve flow direction. . confirm that cock valve ( ) is open (handle is parallel to valve body). . open fully the upstream isolating
valve and slowly open the downstream isolating valve, to fill-up, carefully, the consumers' line downstream from the valve. . vent air from the valve's control loop by loosening cover tube fitting at the highest point, allowing all air to bleed. then retighten the tube fitting. . the ir- - -r is factory...
https://www.bermad.com/wp-content/uploads/2016/05/IR-420-50-R-iom-1.5-4inch.pdf
correct any damaged accessories, piping, tubing, or fittings. commissioning & calibration: . confirm that the in-line filter arrow [ a] direction is in the valve flow direction. . allow the valve to start regulation by positioning the cock valve ( ) handle on port auto. . open fully the upstream isolating
valve and slowly open the downstream isolating valve, to fill-up, carefully, the consumers' line downstream from the valve. . vent air from the valve's control loop by loosening cover tube fitting at the highest point, allowing all air to bleed. then retighten the tube fitting. . the ir- - -rxz is factory...
https://www.bermad.com/wp-content/uploads/2016/05/IR-420-50-RXZ-iom-1.5-4inch.pdf
correct any damaged accessories, piping, tubing, or fittings. commissioning & calibration: . confirm that the in-line filter arrow [ a] direction is in the valve flow direction. . allow the valve to start regulation by positioning the cock valve ( ) handle on port auto. . open fully the upstream isolating
valve and slowly open the downstream isolating valve, to fill-up, carefully, the consumers' line downstream from the valve. . vent air from the valve's control loop by loosening cover tube fitting at the highest point, allowing all air to bleed. then retighten the tube fitting. . the ir- - -brz is factory...
https://www.bermad.com/wp-content/uploads/2016/05/IR-420-50-bRZ.pdf
commissioning & calibration: . confirm that t the in-line filter arrow direction is in the valve flow direction. . confirm that cock valve ( ) is open (handle is parallel to valve body). note: for opening valve, confirm hydraulic pressure command in the hydraulic relay ( -m). . open fully the upstream isolating
valve and slowly open the downstream isolating valve, to fill-up, carefully, the consumers' line downstream from the valve. . vent air from the valve's control loop by loosening cover tube fitting at the highest point, allowing all air to bleed. then retighten the tube fitting. . the ir- -m - -r is...
https://www.bermad.com/wp-content/uploads/2016/05/IR-420-54-R.pdf
pressure reducing hydrometer, to prevent debris from damaging valve operation. . commissioning & calibration: . confirm that the in-line filter ( a) arrow direction is in the valve flow direction. . confirm that the cock valve ( ) is open (handle is parallel to valve body). . open fully the upstream isolating
valve and slowly open the downstream isolating valve, to fill-up, carefully, the consumers' line downstream from the valve. . vent air from the valve's control loop by loosening cover tube fitting at the highest point, allowing all air to bleed. then retighten the tube fitting. . the ir- -m -r is factory...
https://www.bermad.com/wp-content/uploads/2016/05/IR-920-M0-R.pdf
hydrometer, to prevent debris from damaging valve operation. commissioning & calibration: . confirm that the in-line filter arrow [ a] direction is in the valve flow direction. . allow the valve to start regulation by positioning the cock valve ( ) handle on port auto. . open fully the upstream isolating
valve and slowly open the downstream isolating valve, to fill-up, carefully, the consumers' line downstream from the valve. . vent air from the valve's control loop by loosening cover tube fitting at the highest point, allowing all air to bleed. then retighten the tube fitting. . the ir- -m -rxz is...
https://www.bermad.com/wp-content/uploads/2016/05/IR-920-M0-RXZ.pdf
hydrometer, to prevent debris from damaging valve operation. commissioning & calibration: . confirm that the in-line filter arrow [ a] direction is in the valve flow direction. . allow the valve to start regulation by positioning the cock valve ( ) handle on port auto. . open fully the upstream isolating
valve and slowly open the downstream isolating valve, to fill-up, carefully, the consumers' line downstream from the valve. . vent air from the valve's control loop by loosening cover tube fitting at the highest point, allowing all air to bleed. then retighten the tube fitting. . the ir- -m -kbz is...
https://www.bermad.com/wp-content/uploads/2016/05/IR-920-M0-bKZ.pdf